GUIDE BLADE ACTUATOR INSPECTION [MZR-CD (RF Turbo)]
id0113f1807200
1. Disconnect the vacuum hose from the guide blade actuator.
2. Connect the vacuum pump to the guide blade actuator.
am3zzw00004114
|
3. Apply vacuum and verify that the rod moves as specified.
Specification
Vacuum (kPa {mmHg, inHg}) |
Rod movement |
---|---|
Below –21.0 {–158, –6.22}
|
Starts to move
|
Above –51.5 {–386, –15.2}
|
Fully pulled
|